EN 40 — certificate
Automatically extracted document text. Layout, tables and drawings may not be reproduced correctly. Refer to the original document for technical data, units and requirements.
- Document revision
- Not stated in the source
- Status
- Current applicability requires manufacturer or issuer confirmation
Source pages
Document text
Certificate of constancy of performance
1608 CPR P029
In compliance with Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the Construction Products
Regulation or CPR), this certificate applies to the construction products:
Steel lighting columns
whose characteristics are detailed in the attached annex,
produced by or for
Pali Campion Srl
Via Alcide De Gasperi, 45/B 45025 Fratta Polesine RO-IT
and produced in the manufacturing plant(s)
Fratta Polesine RO-IT
This certificate attests that all provisions concerning the assessment and verification of performance described in Annex ZA of the
standard
EN 40-5:2002
under system 1 are applied and that
the product fulfils all the prescribed requirements set out above.
This certificate was first issued on 18/03/2005 and will remain valid as long as the test method and/or factory production control
requirements included in the harmonised standard, used to assess the performance of the declared characteristics, do not change, and
the product, and the manifacturing conditions in the plant are not modified significantly.
The Director
Current issue: 12/03/2021
Roberto Pieroncini
Pagina 1
ATTACHMENT 1 TO CERTIFICATE 1608 CPR P029
Characteristics for
Steel lightning columns according to EN 40-5
Name Total height Configuration
(m) (position of the lantern)
Welded columns with rectangular/square section
Welded stepped cylindrical columns
Welded tapered columns with circular section Up to 20 m Post top
Welded tapered columns with octagonal or
polygonal section
Welded columns with rectangular/square section
Welded stepped cylindrical columns
Welded tapered columns with circular section Up to 18 m With brackets
Welded tapered columns with octagonal or
polygonal section
Characteristic
Wind reference load (m/s)
2
Resistance to horizontal loads Windage area to wind of the lantern (m )
Weight of the lantern (kg)
Maximum horizontal deflection (%)
Performance under vehicle impact Classe 0
Durability Hot dip zinc coating to EN ISO 1461
first issue: 18/03/2005 The Director
current issue: 12/03/2021 Roberto Pieroncini
Pagina 2
ATTACHMENT 2 TO CERTIFICATE 1608 CPR P029
Characteristics for
Steel lightning columns according to EN 40-5
Declared performance under vehicle impact according to EN 12767:2019
Name Design condition Total Height Configuration
(according to EN 40-3-3) (m) (position of the lantern)
Conical columns with foundation: SAVE50 Tubular columns with Mup 8,89kNm 5m Post top
Conical columns with foundation: SAVE51 Tubular columns with Mup 8,89kNm 5m With bracket 1 m
Conical columns with foundation: SAVE52 Tubular columns with Mup 8,89kNm 5m With bracket 2 m
Conical columns with foundation: SAVE60 Tubular columns with Mup 8,89kNm 6m Post top extended 1 m
Conical columns with foundation: SAVE61 Tubular columns with Mup 8,89kNm 6m With bracket 1x1 m
Conical columns with foundation: SAVE62 Tubular columns with Mup 8,89kNm 6m With bracket 1x2 m
Conical columns with foundation: SAVE70 Tubular columns with Mup 8,89kNm 7m Post top extended 2 m
Conical columns with foundation: SAVE71 Tubular columns with Mup 8,89kNm 7m With bracket 2x1 m
Conical columns with foundation: SAVE72 Tubular columns with Mup 8,89kNm 7m With bracket 2x2 m
Characteristic
Performance under vehicle impact Speed class: 70 Km/h
according to EN 12767, as reported in: Energy absorption class: LE
Report 0028_ME_HRB_18
Report 0030_ME_HRB_18 Safety Class: C
and as per update standard reported in: ASI: 0,6
Report 0081_ME_HRB_20_1 THIV: 24 km/h
Backfill type: standard aggregates – S type
ATLANTECH Lux Small Device
Foundation
In accordance to the Installation Manual:
ATLANTECH LUX Installation Manual
Collapse mode Separation mode – SE class
Direction class Single directional – SD class
Detached elements with a mass greater No
than 2 kg
first issue: 18/03/2005 The Director
current issue: 12/03/2021 Roberto Pieroncini
Pagina 3
CONFIGURATION LIGTHING COLUMN SAVE 5m - 6m - 7m
Pagina 4
ATTACHMENT 2 TO CERTIFICATE 1608 CPR P029
Characteristics for
Steel lightning columns according to EN 40-5
Declared performance under vehicle impact according to EN 12767:2019
Name Design condition Total Configuration
(according to EN 40-3-3) Height (position of the lantern)
(m)
Conical columns with foundation: SAVE80 Tubular columns with Mup 10,07kNm 8m Post top
Conical columns with foundation: SAVE81 Tubular columns with Mup 10,07kNm 8m With bracket 1 m
Conical columns with foundation: SAVE82 Tubular columns with Mup 10,07kNm 8m With bracket 2 m
Conical columns with foundation: SAVE90 Tubular columns with Mup 10,07kNm 9m Post top extended 1 m
Conical columns with foundation: SAVE91 Tubular columns with Mup 10,07kNm 9m With bracket 1x1 m
Conical columns with foundation: SAVE92 Tubular columns with Mup 10,07kNm 9m With bracket 1x2 m
Conical columns with foundation: SAVE100 Tubular columns with Mup 10,07kNm 10 m Post top extended 2 m
Conical columns with foundation: SAVE101 Tubular columns with Mup 10,07kNm 10 m With bracket 2x1 m
Conical columns with foundation: SAVE102 Tubular columns with Mup 10,07kNm 10 m With bracket 2x2 m
Characteristic
Performance under vehicle impact Speed class: 50 Km/h - 70 Km/h
according to EN 12767, as reported in:
Energy absorption class: HE
Report 0027_ME_HRB_18
Report 0030_ME_HRB_18 Safety class: C
and as per update standard reported in: ASI: 0,8
Report 0081_ME_HRB_20_1 THIV: 27 km/h
Backfill type: standard aggregates – S type
ATLANTECH Lux Plus Device
Foundation
In accordance to the Installation Manual:
ATLANTECH LUX Installation Manual
Collapse mode No separation collapse mode – NS class
Direction class Single directional – SD class
Detached elements with a mass greater Yes, the lamp
than 2 kg
first issue: 18/03/2005
The Director
current issue: 12/03/2021
Roberto Pieroncini
Pagina 5
CONFIGURATION LIGTHING COLUMN SAVE 8m - 9m - 10m
Pagina 6