Passive safety — technical document
Automatically extracted document text. Layout, tables and drawings may not be reproduced correctly. Refer to the original document for technical data, units and requirements.
- Document revision
- Not stated in the source
- Status
- Current applicability requires manufacturer or issuer confirmation
Source pages
Document text
Certificate of constancy of performance
1608 CPR P029
In compliance with Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the Construction Products
Regulation or CPR), this certificate applies to the construction products:
Steel lighting columns
whose characteristics are detailed in the attached annex,
produced by or for
Pali Campion Srl
Via Alcide De Gasperi, 45/B 45025 Fratta Polesine RO-IT
and produced in the manufacturing plant(s)
Pali Campion Srl, Fratta Polesine Rovigo (Italia);
Technomast Ltda, Campo Largo, Curitiba - Paraná (Brasile)
This certificate attests that all provisions concerning the assessment and verification of performance described in Annex ZA of the
standard
EN 40-5:2002
under system 1 are applied and that
the product fulfils all the prescribed requirements set out above.
This certificate was first issued on 18/03/2005 and will remain valid as long as the test method and/or factory production control
requirements included in the harmonised standard, used to assess the performance of the declared characteristics, do not change, and
the product, and the manifacturing conditions in the plant are not modified significantly.
Current issue: The Director
06/12/2024 Rev.01
Roberto Pieroncini
Pagina 1
ATTACHMENT 1 TO CERTIFICATE 1608 CPR P029
Characteristics for
Steel lightning columns according to EN 40-5
Name Total height Configuration
(m) (position of the lantern)
Welded columns with rectangular/square section
Welded stepped cylindrical columns
Welded tapered columns with circular section Up to 20 m Post top
Welded tapered columns with octagonal or
polygonal section
Welded columns with rectangular/square section
Welded stepped cylindrical columns
Welded tapered columns with circular section Up to 18 m With brackets
Welded tapered columns with octagonal or
polygonal section
Characteristic
Wind reference load (m/s)
Resistance to horizontal loads Windage area to wind of the lantern (m2)
Weight of the lantern (kg)
Maximum horizontal deflection (%)
Performance under vehicle impact Classe 0
Durability Hot dip zinc coating to EN ISO 1461
first issue: 18/03/2005 The Director
current issue: 06/12/2024 Rev.01 Roberto Pieroncini
Pagina 2
ATTACHMENT 2 TO CERTIFICATE 1608 CPR P029
Characteristics for
Steel lightning columns according to EN 40-5
Declared performance under vehicle impact according to EN 12767:2019
Product
Performances
Characteristicsa)
Speed class: 50 70 100 100
Energy absorption
LE LE NE LE
category
Tubolar steel lightning Occupant safety class: C C C D
columns with height
Backfill type S S S S
up to 7 m, Mup<8.89kN
Collapse mode SE SE SE SE
Direction class MD MD MD MD
Risk of roof indentation 0 0 0 0
Device with foundation Atlantech Lux Small
Installation Compliant with the installation Manual: Manuale di Installazione Atlantech Lux /Save
a)Others tubular steel lighting columns covered by this certificate according to EN40-5 are considered to be Class 0
first issue: 18/03/2005 The Director
current issue: 06/12/2024 Rev.01 Roberto Pieroncini
Pagina 3
ATTACHMENT 2 TO CERTIFICATE 1608 CPR P029
Characteristics for
Steel lightning columns according to EN 40-5
Declared performance under vehicle impact according to EN 12767:2019
Product
Performances
Characteristicsa)
Speed class: 50 70 100 100
Energy absorption
HE HE NE LE
category
Tubolar steel lightning
columns with height Occupant safety class: C C C D
up to 10 m, Backfill type S S S S
Mup<10.07kNm Collapse mode NS NS SE SE
Direction class MD MD MD MD
Risk of roof indentation 0 0 0 0
Device with foundation Atlantech Lux Small Plus
Installation Compliant with the installation Manual: Manuale di Installazione Atlantech Lux /Save
a)Others tubular steel lighting columns covered by this certificate according to EN40-5 are considered to be Class 0
first issue: 18/03/2005
The Director
current issue: 06/12/2024 Rev.01
Roberto Pieroncini
Pagina 4
ATTACHMENT 2 TO CERTIFICATE 1608 CPR P029
Characteristics for
Steel lightning columns according to EN 40-5
Declared performance under vehicle impact according to EN 12767:2019
Product
Performances
Characteristicsa)
Speed class: 50 70 100 100
Energy absorption
HE HE NE LE
category
Tubolar steel lightning
columns with height Occupant safety class: C C C D
up to 12 m, Backfill type S S S S
Mup<12.60kNm Collapse mode NS NS SE SE
Direction class MD MD MD MD
Risk of roof indentation 0 0 0 0
Device with foundation Atlantech Lux Medium
Installation Compliant with the installation Manual: Manuale di Installazione Atlantech Lux /Save
a)Others tubular steel lighting columns covered by this certificate according to EN40-5 are considered to be Class 0
first issue: 18/03/2005
The Director
current issue: 06/12/2024 Rev.01
Roberto Pieroncini
Pagina 5