Certificate of constancy of performance
                                               1608 CPR P029
In compliance with Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the Construction Products
Regulation or CPR), this certificate applies to the constructions product:


                                             Steel lighting columns
                                       whose characteristics are detailed in the attached annex,

                                                          produced by or for


                                                   Pali Campion Srl
                           Via Alcide De Gasperi, 45/B 45025 Fratta Polesine RO-IT
                                             and produced in the manufacturing plant(s)

                                                    Fratta Polesine RO-IT
This certificate attests that all provisions concerning the assessment and verification of performance described in Annex ZA of the
standard

                                                     EN 40-5:2002
under system 1 are applied and that
                  the product fulfils all the prescribed requirements set out above.
This certificate was first issued on 18/03/2005 and will remain valid as long as the test method and/or factory production control
requirements included in the harmonised standard, used to assess the performance of the declared characteristics, do not change, and
the product, and the manifacturing conditions in the plant are not modified significantly.

                                                                                        The Director
     Current issue:       14/05/2018                                                 Ing. Dario Agalbato




                                                                                                                      Pagina 1


APPENDIX 1 TO CERTIFICATE                      1608 CPR P029
                                               Characteristics for
                        Steel lightning columns according to EN 40-5
                     Name                             Total height                      Configuration
                                                          (m)                      (position of the lantern)
Welded columns with rectangular/square section
Welded stepped cylindrical columns
Welded tapered columns with circular section           Up to 20 m                           Post top

Welded tapered columns with octagonal or
polygonal section
Welded columns with rectangular/square section
Welded stepped cylindrical columns
Welded tapered columns with circular section           Up to 18 m                         With brackets

Welded tapered columns with octagonal or
polygonal section



                                                 Characteristic
                                               Wind reference load (m/s)
                                                                                      2
Resistance to horizontal load                  Exposed area to wind of the lantern (m )
                                               Weight of the lantern (kg)
                                               Maximum horizontal deflection (%)
Performance under vehicle impact               Classe 0
Durability                                     Hot dip zinc coating to EN ISO 1461

first issue:     18/03/2005                                                              The Director
current issue:   14/05/2018                                                          ing. Dario Agalbato




                                                                                                               Pagina 2


APPENDIX 2 TO CERTIFICATE                      1608 CPR P029
                                               Characteristics for
                       Steel lightning columns according to EN 40-5
                    Declared performance under vehicle impact according to EN 12767

                 Name                            Design condition             Total Height      Configuration
                                               (according to EN 40-3-3)           (m)        (position of the lantern)
Conical columns with foundation: SAVE50   Tubular columns with Mup 8,89kNm       5m                 Post top
Conical columns with foundation: SAVE51   Tubular columns with Mup 8,89kNm       5m            With bracket 1 m
Conical columns with foundation: SAVE52   Tubular columns with Mup 8,89kNm       5m            With bracket 2 m
Conical columns with foundation: SAVE60   Tubular columns with Mup 8,89kNm       6m          Post top extended 1 m
Conical columns with foundation: SAVE61   Tubular columns with Mup 8,89kNm       6m           With bracket 1x1 m
Conical columns with foundation: SAVE62   Tubular columns with Mup 8,89kNm       6m           With bracket 1x2 m
Conical columns with foundation: SAVE70   Tubular columns with Mup 8,89kNm       7m          Post top extended 2 m
Conical columns with foundation: SAVE71   Tubular columns with Mup 8,89kNm       7m           With bracket 2x1 m
Conical columns with foundation: SAVE72   Tubular columns with Mup 8,89kNm       7m           With bracket 2x2 m




                                                  Characteristic

Performance under vehicle impact              Speed class: 70 Km/h
according to EN 12767, as reported in:
                                              Energy absorbtion class: LE
Report 0028_ME_HRB_18
Report 0030_ME_HRB_18                         Safety Class: 3

                                              Device ATLANTECH Lux Small
Foundation                                    In conformity to the Installation Manual:
                                              Manuale installazione ATLENTECH LUX

first issue:     18/03/2005
current issue:   14/05/2018                                                                 Il Direttore
                                                                                       ing. Dario Agalbato




                                                                                                                Pagina 3


CONFIGURATION COLUMNS SAVE 5m - 6m - 7m




                                          Pagina 4


APPENDIX 2 TO CERTIFICATE                        1608 CPR P029
                                                 Characteristics for
                       Steel lightning columns according to EN 40-5
                    Declared performance under vehicle impact according to EN 12767

                 Name                              Design condition               Total         Configuration
                                                 (according to EN 40-3-3)         Height     (position of the lantern)
                                                                                   (m)
Conical columns with foundation: SAVE80     Tubular columns with Mup 10,07kNm      8m               Post top
Conical columns with foundation: SAVE81     Tubular columns with Mup 10,07kNm      8m          With bracket 1 m
Conical columns with foundation: SAVE82     Tubular columns with Mup 10,07kNm      8m          With bracket 2 m
Conical columns with foundation: SAVE90     Tubular columns with Mup 10,07kNm      9m       Post top extended 1 m
Conical columns with foundation: SAVE91     Tubular columns with Mup 10,07kNm      9m         With bracket 1x1 m
Conical columns with foundation: SAVE92     Tubular columns with Mup 10,07kNm      9m         With bracket 1x2 m
Conical columns with foundation: SAVE100    Tubular columns with Mup 10,07kNm     10 m      Post top extended 2 m
Conical columns with foundation: SAVE101    Tubular columns with Mup 10,07kNm     10 m        With bracket 2x1 m
Conical columns with foundation: SAVE102    Tubular columns with Mup 10,07kNm     10 m        With bracket 2x2 m




                                                    Characteristic
Prestazione in caso di impatto da veicolo      Speed class: 70 Km/h
secondo EN 12767, di cui ai rapporti
                                               Energy absorption class: HE
 Rapporto 0027_ME_HRB_18
 Rapporto 0030_ME_HRB_18                       Safety class: 3

                                               Device ATLANTECH Lux Plus
Foundation                                     In conformity to the Installation Manual:
                                               Manuale installazione ATLANTECH LUX

first issue:     18/03/2005
current issue:   14/05/2018                                                                Il Direttore
                                                                                      ing. Dario Agalbato




                                                                                                                Pagina 5


CONFIGURATION COLUMNS SAVE 8m - 9m - 10m




                                           Pagina 6